Common faults of five-party communication in elevators
Leave a message
There are generally several reasons for the wireless five-party intercom equipment in elevators
(1) Wireless signal issue: The main and extension antennas are placed outdoors.
(2) The built-in intercom devices were not removed, and the mixed use of intercom devices caused interference. All the original intercom devices were removed.
⑶ The cables used for connecting the communicator carry voltage and current interference. Spare passive cables should be adopted.
There are generally several reasons for the wired five-party intercom equipment in elevators
(1) The communicator is aging. Replace it with a new one.
(2) Aging of the lines, replace the lines;
⑶ The wire diameter is too thin, the pulling distance is too far, and the attenuation is severe. Replace the wire material.
The five-party intercom equipment for IP elevators is usually a problem with the setup
(1) Extension, play, and record volume adjustment. Turn up the play and record volumes a bit.
When the sound of the five-party intercom equipment in the elevator is low, you can refer to the above reasons for troubleshooting